Add to Cart
HT11 10K 10kva Tower UPS Uniterruptible Power Supply Zero Transfer Time
JET-HT11 10K Online High-Frequency UPS
10KVA
1/1 Phase
Power Factor 0.8
6-10KVA Online High-Frequency UPS, has tower and rack installation. It is an ideal power supply solution for small capacity scenes based on online dual transform technology, which can eliminate all kinds of power grid problems. The battery is built in the standard machine.
Such as Model HT11 10K, is 10KVA tower type UPS, 1 / 1 Phase, built-in battery, with power factor 0.8. As we known, grid is not stable, if UPS conversion time is zero, that is more security and reliable.
JET-HT11 series is applied in servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
Key Features
1, A very wide range of input voltage and frequency, even in remote parts of electric power environment is very bad to normal power supply, reduce the number of battery discharge, improve the service life of the battery.
2, Double conversion design, Zero transfer/complete isolation of input AC.
3, Advanced DSP numerical control technology application, the performance of UPS is more stable, more superior quality.
4, True sine-wave output with less than 3% THD.
5, Microprocessor control ensures high reliability
6, The load power factor is 0.8.
7, Wide input voltage range and frequency range fit to harsh power grid condition.
HT11 10K Specifications
Model technical parameters | 10K | 10KL (R) | |
Nominal Capacity | 10KVA / 8KW | ||
Nominal | Voltage | 220VAC | |
AC Input | Nominal Frequency | 50Hz | |
Voltage Range | 120~275VAC ±5 | ||
Frequency Range | 45~55Hz ±0.5Hz | ||
Bypass Voltage | 80VAC × (1±5%) ~ 285VAC × (1±5%) | ||
Battery Input | Battery Pack | 192VDC (Optional up to 240V) | |
Batteries Capacity &Qty | 12VDC x 16 (Optional up to 20 sets) | ||
Charging Current | 4A | ||
AC Output | Voltage | 220VAC ±1% (Invert Output) | |
Frequency | 46~54Hz (Normal AC Input) 50Hz ±1% (Abnormal AC Input) | ||
Wave Form | THD<3% (Linear Load) Sine Wave, THD<8% (Non-Linear Load) | ||
Power Factor | 0.8 | ||
Overload Cap. | 105~125% Bypass after 1mins | ||
Communication & Monitoring Function | RS232, dry contact | ||
Tower Type | Weight (kgs) | 59 | 19.5 |
Dimension (W x H x D) (mm) | 248×620×500 | 248×460×500 | |
Rack Type | Weight (kgs) | 19.5 | 19.5 |
Dimension (W x H x D) (mm) | 640×130×440 | 640×130×440 |
Remark: 10KVA UPS also has rack mount installation model, the differences are list as above.
Models:
H: High-frequency
T: Tower type
R: Rack type