Packaging Details :Wooden Case
Voltage measurement range :AC 0~450V, Display Resolution: 0.1V, Precision: ±0.5%
Current measurement range :AC 0~100A, Display Resolution: 0.1A, Precision: ±0.5%
Power measurement range :0~20 KVA, Display Resolution: 0.1KVA, Precision: ±1%
Power factor measurement range :0.001~1.000, Display Resolution: 0.001, Precision: ±0.5%
Type :Resistive load bank
Application :Generator,UPS,Battery,Power Plant,Generator Load Test
Product name :10KW Load Bank,AC variable resistive load bank for sale,battery test load bank
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

20KW Portable Load Bank For Generator Load Testing 3 Phase Load Bank

JET-ACO Series AC Resistive Load Bank

A load testing is part of the maintenance for a generator.

There are multiple reasons generator should undergo a load bank test on an annual basis, including but not limited to the following:

  • Verifies the generator capabilities opposed to just routinely starting it up.
  • Problems discovered early can be significantly less expensive and prevents future major issues.
  • Helps to avoid wet-stacking and cleans out carbon deposits.
  • Verifies the engine cooling systems will perform while under load.
  • Provides assurance that the generator should work properly when you need it most.

Test:

  • Three-phase voltage
  • Current
  • Active power& reactive power
  • Apparent power
  • Power factor
  • Frequency
  • Running time
  • Energies of generators and UPS

Functions & Features

◆ Test three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time, energies of generators and UPS.

◆ It has harmonic analysis of 2-50 orders of harmonic content and the total harmonic content for voltage or current.

◆ Set/adjust discharging power according to performance parameters and detection requirements

◆ Set discharging time, timing to automatic shut-off load, discharge off and alarm operator

◆ Set over/under voltage protection threshold value, it can shut off load, terminate discharging and alarm user automatically.

◆ Large LCD screen, friendly interface. English menu and easy operation.

◆ Parallel operation function to carry out multi sets load operation by RS 485 communication

◆ Built-in storage save 30 groups of test data, which can be viewed, deleted and export into SD card.

◆ Start/stop discharging control by Serial port, and detect data real time operation etc.; The storage data can be uploaded to PC by serial port or SD card, and the upper computer’s software can analyze data and pattern and print report etc.

◆ Overheating and over current protection function, it can turn off load, terminate discharging and alarm automatically when over temperature and over current.

◆ Set at most 5 groups power, load process automatically according to the setting power and operation time after being turned on.

Specifications

Mode JET-ACO 380/02 JET-ACO 380/04 JET-ACO 380/10
Load voltage Three-phase AC380V, Single-phase AC220V
Operating power

Stand-alone: Max 20KW (Three-phase 380V)

Max 6KW (Singly-phase 220V)

Stand-alone: Max 40KW (Three-phase 380V)

Max 13KW (Singly-phase 220V)

Stand-alone: Max 100KW (Three-phase 380V)

Max 30KW (Singly-phase 220V)

Cooling mode FCT (Fan control Temperature)
Communication Mode RS232, RS485 and SD card
Display mode 8-inch TFT
Voltage measurement range AC 0~450V, Display Resolution: 0.1V, Precision: ±0.5%
Current measurement range AC 0~100A, Display Resolution: 0.1A, Precision: ±0.5% AC 0~150A, Display Resolution: 0.1A, Precision: ±0.5% AC 0~300A, Display Resolution: 0.1A, Precision: ±0.5%
Frequency measurement range 40~60 Hz, Display Resolution: 0.01Hz, Precision: ±0.2%
Power measurement range 0~20 KVA, Display Resolution: 0.1KVA, Precision: ±1% 0~40 KVA, Display Resolution: 0.1KVA, Precision: ±1% 0~100 KVA, Display Resolution: 0.1KVA, Precision: ±1%
Power factor measurement range 0.001~1.000, Display Resolution: 0.001, Precision: ±0.5%
Discharging Time (0~19 hours and 59 minutes) adjustable continuously
Quantity of Parallel operation 1~99 sets
Recording Period 6~999 Seconds
Temperature measurement range -20~100℃,Display resolution: 1℃, precision:±1℃
Insulating strength Input≥AC1500V, Output≥AC500V
Working environment

Working Temperature: (-20~55)℃,

Storage Temperature: (-45~75)℃

Relative humidity: 90%(40±2℃)

Atmospheric pressure: (70~106) KPa

Working power supply Single-phase AC220V±10, 50Hz
MTTF ≥50000h
Dimensions(mm) 420×500×750mm 680×600×900mm 680×600×900mm
Weight 30kg 50kg 70kg

Service

1. Pre-service

-- 7/24 online service for your consult.

-- Help choose right model, and a series of service, person, advise.

2. Middle service

-- Give you best offer.

-- Provide discount for qty order.

-- Do customer's request.

-- Choose payment term as you convenient.

-- Delivery promptly, and inform you in time.

-- Provide invoice value as you like to decrease your tax.

3. After sale service

-- 1-year warranty service and all life maintenance.

-- Technical engineer are available for oversea training.

-- Free change for some parts.

-- Remote control technical service.

-- Free installation DVD

-- Maintenance plan.

Inquiry Cart 0